Quick assembly: Lightweight components are easy to cut on-site, and the screw-fastened or clip-on connections eliminate wet trades, shortening schedules.

banner
Installation Advantages
10 11, 2025

Quick assembly: Lightweight components are easy to cut on-site, and the screw-fastened or clip-on connections eliminate wet trades, shortening schedules.  

Dimensional stability: Galvanized coating resists moisture warping, keeping ceilings and partition lines true over time.  

Service integration: Open-web sections allow ducts, conduit and piping to pass through without extra notching, saving headroom.  

Fire & acoustic upgrades: When paired with mineral wool and multiple layers of fire-rated board, 60–120 min fire resistance and 45–55 dB sound reduction are readily achieved.  

 

Typical Section Properties (common U-C profiles)

Model

Depth (mm) 

Flange (mm)

Thickness (mm) 

Weight (kg/m)

Moment of Inertia Iₓ (cm⁴) 

Section Modulus Zₓ (cm³) 

UC38

38120.6
0.56
1.480.78

UC50

50150.70.783.201.28

UC60

60200.81.055.901.97


Finishing Compatibility  

Gypsum plasterboard, fibre-cement board, calcium-silicate board, magnesium-oxide board, plywood, MDF, decorative metal panels, stretch-fabric membranes.  

 

Corrosion & Coating Options  

  • Standard: Z120–Z275 g/m² hot-dip zinc (G40–G90).  

  • Enhanced: Zn-Al-Mg alloy coating (150–200 g/m²) for coastal or high-humidity zones.  

  • Optional colour-coated polyester or PVDF top coat for exposed grid applications.  

 

Sustainability Credentials  

  • 100 % recyclable steel; typical recycled content 25–30 %.  

  • Factory roll-forming generates <2 % scrap, all of which is re-melted.  

  • Light weight reduces transport energy and structural load, allowing smaller concrete/steel primary frames.  

 

Design Codes & Testing  

  • EN 14195:2005 (EU), ASTM C645 & C754 (US), GB/T 11981-2020 (CN).  

  • Load-span tables verified by third-party tests for 1/240 deflection limit at 1.5 × design load.  

  • Seismic tested per ICC-ES AC 261, suitable for S_DS up to 2.0 g.  

 

Packing & Logistics  

  • Bundled in 3 000 mm lengths (custom 2 400–6 000 mm), 10-piece shrink-wrapped packs, 50–60 bundles per pallet.  

  • One 40 ft HC container loads ≈ 25 t (≈ 22 km of UC50 stud), enough for 4 000–5 000 m² of partition.  

 

Installation Tips  

1. Maintain 300–400 mm end-bearing on tracks; use acoustic isolating pads where partitions meet structural slabs.  

2. Stagger board joints on opposite sides by ≥ 600 mm; leave 3 mm perimeter gap filled with acoustic sealant.  

3. For heavy fixtures (basins, TVs), back-to-back double studs or timber noggins should be pre-installed before boarding.  

 

Future Trends  

  • Prefabricated “cassettes” with factory-fixed boards and pre-routed service holes cut site labour by 30 %.  

  • 3-D roll-forming machines now produce variable-depth studs (deeper at mid-span) to save 8–12 % steel weight.  

  • BIM-embedded libraries allow direct export of cut lists and CNC roll-forming files, reducing detailing errors to near zero.


Share: